Loading...

OFFLINE

Loading...

BUSY

Wi-Fi Signal Strength
dBm
offline time:
Public QR (Read-Only)

    • Pump start when water level reach 75% or lower.
    • Pump stop when water level reach 93% or bigger.
    • Pump stop if water level get closer to the sensor blind area defined at sensor linked settings.
    • Pump stop if the sensor is offline or controller lose internet connection.
    • This is an experimental feature; do not use it without supervision.
      Ensure all necessary precautions are taken, as it may not work under your specific conditions.
      Use Advanced Settings
      to customize the smart mode for factors like water tank size, pump flow, and other variables.
    • Carefully read the WiFi Water Level S1 sensor installation guide before using this feature. Ensure the sensor inside the water tank is not too close to the water inlet or floating valve and consistently provides accurate water level readings.
  • Enable the smart off conditions: End Level, Blind Area, Not Water Flow, Offline Sensor.
    If enabled, the pump will stop when the water level reaches End Level % or Blind Area, if the linked sensor goes offline, or if no incoming water flow is detected during the Flow Check period.

    Don't Depends On: Smart Mode
  • Enable the smart on condition: Start Level.
    If enabled, the pump will start if water level reaches or falls below Start Level %.

    Requires: Smart Mode
  • %

    Pump will start if the water level reaches or falls below this percentage.

    Requires: Smart On and Smart Mode
  • %

    Pump will stop if the water level reaches or pass above this percentage.

    Requires: Smart Off and Smart Mode
  • minutes

    When the pump is ON, it checks every X minutes whether it is providing incoming flow. If no flow is detected, the pump will stop and attempt to restart after 3 hours.

    It is recommended to use a value at least three times the sensor update frequency or higher to ensure proper collection of sensor data. Additionally, depending on your specific flow speed and water tank capacity, more or less time may be required to move 1 centimeter effectively.

    The maximum value is approximately 10 times the sensor update frequency plus 2 minutes, as the pump controller currently stores only the last 10 sensor updates for this feature.

    Requires: Smart Mode
    Don't Depends On: Smart Off
  • CM

    The pump stop if reach the sensor blind distance.

      Common Sensor Blind Distances
    • AJ-SR04M: 20 CM
    • RCWL-1670: 2 CM
    Requires: Smart Off and Smart Mode
    Don't Depends On: Smart Mode if Safe Mode in ON
  • GTM-4

    Comma separated list of GMT-4 hours when the pump will not start. Example: 23,0,1,2,3,4,5,6,7,8,9
    Useful to avoid pump start at specific hours, use GMT-4 timezone.

    Local Timezone Converter: -

    If the pump is running and Smart Mode is enabled, it will stop when Disabled Hours begin.

    Requires: Smart Mode
    Don't Depends On: Smart Off
  • Requires: Smart Off
    Don't Depends On: Smart Mode